Series 200 Monitor
The Series 200 can be hand held or fixed in position. It is a simple, easy-to-use, low-cost monitor that only displays the gas concentration. The monitor is compatible with the full range of Aeroqual gas sensors and is thus capable of measuring ozone, volatile organic compounds (VOC's), ammonia and carbon monoxide.
Monitor Specifications
Series 200 Monitor Base
Measurement units | ppm |
Removable / replaceable sensor head | Yes |
On-board alarm | No |
Alarm status displayed | No |
Low battery indication | Yes |
Alarm mute function | No |
Sensor condition status | Yes |
Stand-by mode | Yes |
External signal for alarms & control | None |
External signal functions | None |
Analogue output | None |
Power supply | 12 VDC, 800 mA |
Rechargeable battery pack (2 x options) | Standard - 9.6V ( 940mA/hr Ni-Cd) Long life - 9.6V (2100mA/hr Ni-MH) |
Portable | Yes |
Permanently fixable | Screw fix |
Remote Sensor Capability | Yes |
Enclosure rating | IP20 & NEMA 1 equivalent |
Size (with sensor head) | 195 x 122 x 54 (mm); 7? x 4¾ x 2? (in) |
Weight (with sensor head and battery) | < 460 g; < 16 oz |
Approvals | Part 15 of FCC Rules EN 50082-1: 1997 EN50081-1: 1992 |
Ozone Sensor Head Specifications
Sensor Heads | Low | High | Leak |
Measurement range | 0.000 - 0.500 ppm | 0.50 - 20.00 ppm | 0.00 - 50.00 ppm |
Accuracy | < 0.008 ppm (0 - 0.100 ppm) ± 10% (0.100 - 0.500 ppm) |
± 10% (0.20 - 2.00 ppm) ± 15% (2.00 - 20.00 ppm) |
± 20%, 15 seconds after Reset |
Resolution | 0.001 ppm | 0.01 ppm | 0.01 ppm |
Controlled Atmosphere | Available on Request | Available on Request | Available on Request |
Version | |||
T90 Response | < 60 seconds (T90) | < 35 seconds (T90) | < 10 seconds (T90) |
Sensor type | Gas-sensitive semiconductor | ||
Operating temperature range | -5°C to 50°C; 23°F to 122°F | (sensor head and base unit) | |
Relative humidity limit | 95% maximum (sensor head and base unit) |
VOC Sensor Head Specification*
Measurement range | 0 to 400 ppm toluene |
Accuracy | < +/- 10 ppm (0 - 200 ppm) < +/- 10% ( > 200 ppm) |
T90 response | < 60 s |
Sensor type | Gas-sensitive semiconductor |
Operating temperature range | -20°C to 60°C |
Operating relative humidity range | 5 to 95% non-condensating |
* Specific Calibrations to other VOC's available - contact Aeroqual Sales
Ammonia Sensor Head Specification
Measurement range | 0 to 1000 ppm |
Accuracy | < +/- 5 ppm (0 - 100 ppm) < +/- 10% ( 100 - 1000 ppm) |
T90 response | < 60 s |
Sensor type | Gas-sensitive semiconductor |
Operating temperature range | -20°C to 60°C |
Operating relative humidity range | 5 to 95% non-condensating |
CO Sensor Head Specification
Measurement range | 0 to 2000 ppm carbon monoxide |
Accuracy | < +/- 10 ppm in the range 0 to 400 ppm |
T90 response | < 150 s |
Sensor type | Gas-sensitive semiconductor |
Operating temperature range | 0°C to 70°C |
Operating relative humidity range | 5 to 95% non-condensating |
Approvals | UL 2034, BS 7860 |
Additional Product Information